2D to 3D · Piping & P&ID drawings

Turn a flat P&ID into a 3D model you can explore.

Upload the PDF of a P&ID or piping schematic. ANMASI reads the equipment, lines, valves and instruments, marks the few spots it is not sure of, and builds an interactive 3D model your team can open on site.

In
PDF sheet
Out
3D model
Share
Link

01 / Reads

It reads the sheet the way a fitter does.

Every symbol on the drawing becomes a part of the model, with the tag, the size and the line it sits on. Point at a group to see what it picks up.

1122334455667788AABBCCDDEEDN50 · WDN50 · WDN80 · WDN50 · WDN50 · WDN40 · NaOHDN40 · NaOHDN65 · NaOHDN40 · NaOHDN40 · NaOHDN25 · HNO3DN25 · HNO3DN25 · HNO3DN50 · STDN32 · STDN50 · STDN32 · STDN32 · STDN25 · CONDN25 · CONDN25 · CONDN32 · CONDN32 · CONDN80 · CIP-SDN65 · CIP-SDN65 · CIP-SDN65 · CIP-RDN80 · CIP-SDN65 · CIP-SDN65 · CIP-SDN65 · CIP-RDN80 · CIP-SDN65 · CIP-SDN65 · CIP-SDN65 · CIP-RT-101Water tank10 m³T-102Caustic tank10 m³WATER · mainsHNO3 · dosingNaOH 50 % · unloadSTEAM 6 barCONDENSATEK1-B10.6 m³K1-P1K1-E1CIP 1 · returnCIP 1 · supplyK2-B10.6 m³K2-P1K2-E1CIP 2 · returnCIP 2 · supplyK3-B10.6 m³K3-P1K3-E1CIP 3 · returnCIP 3 · supplyFT01AV-01AV-03K1-AV1K2-AV1K3-AV1HV-02AV-04K1-AV2K2-AV2K3-AV2K1-AV3K2-AV3K3-AV3K1-AV7K2-AV7K3-AV7K1-HV1K2-HV1K3-HV1K1-AV4K1-NRV1PT1TT1FT1K1-AV5QT1K1-V6K2-AV4K2-NRV1PT1TT1FT1K2-AV5QT1K2-AV6K3-AV4K3-NRV1PT1TT1FT1K3-AV5QT1K3-AV6MEDIAW - WaterNaOH - Caustic NaOHHNO3 - Acid HNO3ST - Steam 6 barCON - CondensateCIP-S - CIP supplyCIP-R - CIP returnCIP station, 3 circuitsDesign officeSample Engineering Ltd.Synthetic sample sheet, not a real projectDrawing no. · rev.SCH-CIP-01 · BP&ID · sheet 1/1

02 / Process

Three steps from PDF to model.

  1. 01

    Upload

    Upload the PDF.

    A CAD export or a clean scan of the sheet. No special format, nothing to install.

  2. 02

    Check

    Check the flagged spots.

    Where the drawing is hard to read, the spot is marked with the reason, so you know exactly what to look at.

  3. 03

    Explore

    Explore the model.

    Rotate it, follow a line from end to end, switch media on and off, and send a link to the site.

03 / Sample

Same station, two views.

Point at any valve, pump or line in the drawing and find it in the model, or the other way round. Drag the model to turn it.

1122334455667788AABBCCDDEEDN50 · WDN50 · WDN80 · WDN50 · WDN50 · WDN40 · NaOHDN40 · NaOHDN65 · NaOHDN40 · NaOHDN40 · NaOHDN25 · HNO3DN25 · HNO3DN25 · HNO3DN50 · STDN32 · STDN50 · STDN32 · STDN32 · STDN25 · CONDN25 · CONDN25 · CONDN32 · CONDN32 · CONDN80 · CIP-SDN65 · CIP-SDN65 · CIP-SDN65 · CIP-RDN80 · CIP-SDN65 · CIP-SDN65 · CIP-SDN65 · CIP-RDN80 · CIP-SDN65 · CIP-SDN65 · CIP-SDN65 · CIP-RT-101Water tank10 m³T-102Caustic tank10 m³WATER · mainsHNO3 · dosingNaOH 50 % · unloadSTEAM 6 barCONDENSATEK1-B10.6 m³K1-P1K1-E1CIP 1 · returnCIP 1 · supplyK2-B10.6 m³K2-P1K2-E1CIP 2 · returnCIP 2 · supplyK3-B10.6 m³K3-P1K3-E1CIP 3 · returnCIP 3 · supplyFT01AV-01AV-03K1-AV1K2-AV1K3-AV1HV-02AV-04K1-AV2K2-AV2K3-AV2K1-AV3K2-AV3K3-AV3K1-AV7K2-AV7K3-AV7K1-HV1K2-HV1K3-HV1K1-AV4K1-NRV1PT1TT1FT1K1-AV5QT1K1-V6K2-AV4K2-NRV1PT1TT1FT1K2-AV5QT1K2-AV6K3-AV4K3-NRV1PT1TT1FT1K3-AV5QT1K3-AV6MEDIAW - WaterNaOH - Caustic NaOHHNO3 - Acid HNO3ST - Steam 6 barCON - CondensateCIP-S - CIP supplyCIP-R - CIP returnCIP station, 3 circuitsDesign officeSample Engineering Ltd.Synthetic sample sheet, not a real projectDrawing no. · rev.SCH-CIP-01 · BP&ID · sheet 1/1
2D · drawingSCH-CIP-01 rev B
3D · modeldrag to turn · tap a part

A synthetic sample station, not a real project. The model follows the layout of the drawing; it is not a to-scale plant layout.

04 / Output

What you get for every sheet.

01

An interactive 3D model

Every tank, pump, line and fitting, connected in the order the drawing connects them.

02

Lines by size

Each line carries its DN and medium, so the sizes on the sheet are there at a glance.

03

Media you can tell apart

Each medium keeps the colour it has on the drawing, with its name, and any of them can be hidden.

04

Flagged spots

What the drawing does not make clear is marked with the reason, so you know where to look first.

05

A link for the site

Open the model on a phone or a laptop from a link, next to the line you are building.

05 / On site

The drawing stays in the office. The model goes with the crew.

A shared model opens in the browser of any phone. Turn it to see which way a line runs, tap a valve for its tag, hide the media you are not working on.

SCH-CIP-013D
1122334455667788AABBCCDDEEDN50 · WDN50 · WDN80 · WDN50 · WDN50 · WDN40 · NaOHDN40 · NaOHDN65 · NaOHDN40 · NaOHDN40 · NaOHDN25 · HNO3DN25 · HNO3DN25 · HNO3DN50 · STDN32 · STDN50 · STDN32 · STDN32 · STDN25 · CONDN25 · CONDN25 · CONDN32 · CONDN32 · CONDN80 · CIP-SDN65 · CIP-SDN65 · CIP-SDN65 · CIP-RDN80 · CIP-SDN65 · CIP-SDN65 · CIP-SDN65 · CIP-RDN80 · CIP-SDN65 · CIP-SDN65 · CIP-SDN65 · CIP-RT-101Water tank10 m³T-102Caustic tank10 m³WATER · mainsHNO3 · dosingNaOH 50 % · unloadSTEAM 6 barCONDENSATEK1-B10.6 m³K1-P1K1-E1CIP 1 · returnCIP 1 · supplyK2-B10.6 m³K2-P1K2-E1CIP 2 · returnCIP 2 · supplyK3-B10.6 m³K3-P1K3-E1CIP 3 · returnCIP 3 · supplyFT01AV-01AV-03K1-AV1K2-AV1K3-AV1HV-02AV-04K1-AV2K2-AV2K3-AV2K1-AV3K2-AV3K3-AV3K1-AV7K2-AV7K3-AV7K1-HV1K2-HV1K3-HV1K1-AV4K1-NRV1PT1TT1FT1K1-AV5QT1K1-V6K2-AV4K2-NRV1PT1TT1FT1K2-AV5QT1K2-AV6K3-AV4K3-NRV1PT1TT1FT1K3-AV5QT1K3-AV6
WaterCausticSteamCIP

06 / Start

Bring your next drawing.

Sign in, upload the PDF and open the model when it is ready.